40 Energy Savings Plus Health | INDOOR AIR QUALITY GUIDELINES FOR MULTIFAMILY BUILDING UPGRADES
PRIORITY ISSUE 13.0 OZONE FROM INDOOR SOURCES
ASSESSMENT PROTOCOLS (AP) MINIMUM ACTIONS (MA) EXPANDED ACTIONS (EA)
AP 13.1 Determine the Presence of
Ozone-Producing Equipment
In every dwelling unit where an audit
and/or upgrade will occur, determine
whether any air-cleaning devices de-
signed to intentionally produce ozone
(i.e., ozone generators) are present.
MA 13.1 Avoid Air-Cleaning Equipment
that Intentionally Produces Ozone
Do not install air-cleaning devices
designed to produce ozone (i.e., ozone
generators).
Recommend removal of air-cleaning
devices designed to produce ozone
intentionally, if present.
This cell is intentionally blank.
References for Priority Issue 13.0 Ozone from Indoor Sources:
California EPA Air Resources Board (CARB): Hazardous Ozone-Generating "Air Purifiers"
EPA: Ozone Generators that are Sold as Air Cleaners