IAQA - White Paper Archives

Pinto_A Practical Approach to Assisting Sensitized Individuals

Issue link: https://hi.iaq.net/i/691401

Contents of this Issue

Navigation

Page 10 of 12

IAQA 18th Annual Meeting & Indoor Environment and Energy Expo (IE3) The views and opinions herein are those of the volunteer authors and may not reflect the views and opinions of IAQA. The information is offered in good faith and believed to be reliable but it is provided without warranty, expressed or implied, as to the merchantability, fitness for a particular purpose or any other matter. of their Environmental Relative Moldiness Index (ERMI) sampling process. Their studies showed that a good indication of whether any structure had suffered water damage could be obtained from a single dust sample of the flooring. Building on that government work, there is a growing body of evidence from carefully controlled medical studies that dust samples can be used to predict health concerns for sensitized occupants. One well-known physician, Dr. Ritchie Shoemaker, has even identified core components of an ERMI sample that specifically correlate with health. He compares ERMI-style dust sample results to a score sheet to provide his patients with information about whether a particular space is suitable for their occupation. This process is now migrating to an evaluation of the structure following remediation. Despite not being high-tech, the primary method of removing reservoirs of contaminants from building surfaces is detailed cleaning. Every square inch of the surfaces in the structure are cleaned using HEPA vacuums (sealed and tested with a particle counter to ensure that they are not spreading dust around rather than collecting it), microfiber cloths, and carefully selected cleaning agents. This work is supplemented by air washing (directing compressed air across the surfaces toward an exhaust fan) and air scrubbing (recirculating air through a HEPA-filtered device). Sometimes fogging with water or non-toxic solutions is also utilized to help lift particles from surfaces and give them greater mass so that they are more easily captured. A Word About Ozone A number of contractors are now pitching the process of "treating mold in place" with high levels of ozone instead of removing contaminated materials in a controlled and careful way. They have expanded their promotion to include ozone flooding of structures after remediation as "insurance" against problems from hidden sources.This is bad for normal occupants and could be devastating for the sensitized individual. This approach is so far out of bounds that the New York City guidelines use this pretty clear language: The use of gaseous, vapor-phase, or aerosolized (e.g., fogging) biocides for remedial purposes is not recommended. Using biocides in this manner can pose health concerns for people in occupied spaces of the building and for people returning to the treated space. Furthermore, the effectiveness of these treatments is unproven and does not address the possible health concerns from the presence of the remaining non-viable mold. Other documents from the American Conference of Governmental Industrial Hygienists (ACGIH), the Restoration Industry Association (RIA), and the Institute of Inspection Cleaning and Restoration Certification (IICRC) say the same thing. Several of them specifically call

Articles in this issue

Archives of this issue

view archives of IAQA - White Paper Archives - Pinto_A Practical Approach to Assisting Sensitized Individuals