Page 100 of 144

www.epa.gov/iaq/moisture yy Open weep holes by probing with a wood dowel or stiff wire. NOTE: Care must be taken to prevent damaging flashing when cleaning weeps. • Identify and repair problems before they cause water damage to walls. • Incorporate the results of each inspection into the user's manual and logbook. • Inspect caulking and sealants at junctions of the brickwork and other materials such as windows, doors and expansion joints. Verification of Wall Maintenance • Inspect flashings and counter flashings. Look for loose flashing or missing fasteners, open ends or lap joints, unsealed corners, and rusted or corroded metal. Incorporate completed inspection forms and completed checklists into the user's manual and logbook. 94